Building Permit information
Any other construction 200 sq ft and over requires a building permit.
Any construction of 400 sq ft and over requires a foundation. For residential
accessory.
The final home address will be given at the time of final inspection.
Any construction attached to a dwelling requires a building permit.
To schedule an inspection: Call 734-9490 ext.16
Please have ready: the permit number, property address, contact person and his/her phone number.
Prior to requesting the frame inspection, rough-in inspections for plumbing, electrical
and mechanical must be completed.
Prior to requesting the final inspection, the final plumbing, electrical and
mechanical inspections must be completed.
Building Design
Criteria and Plan Preparation:
-
Wind Load 90
mph 3 second gust Height and exposure
adjustment coefficient is C
-
Snow Load 30
lbs. per sq. ft. (roof)
-
Seismic design
category C
-
Design
Temperature zero degrees Fahrenheit
-
Weathering
Probability rating for concrete is Severe.
-
Frost line
depth is 24 below finished grade.
-
Maximum soil
bearing pressure is 1500 lbs. per sq. ft.
unless a soils investigation is provided
-
Foundation
walls over 9 ft. height require engineering
design
-
Foundation
walls over 3-6 shall be a minimum 8-inch
thickness
-
Buildings over
two-story height or of unusual design may
require engineering design
-
Truss design
drawings shall be in accordance with R802.10
and retained on site.
NO WORK TO BE DONE UNTIL PERMIT IS ISSUED |